What is the recommended seeding density for non-adherent cells for a chemotaxis assay?
For each chamber of the µ-Slide Chemotaxis we recommend to seed 6 µl cell suspension in a gel matrix with a concentration of 3x106 cells/ml. Thus, the calculated number of cells per chamber is 18,000.